Part Number STH12 9/10 99
Beverage
dispensed is too
sweet:
Is the ratio (brix) of
the drink correct?
Flow control out of
adjustment
Adjust the flow control.
Insufficient soda flow
due to low carbonator
pressure
Adjust CO
2
pressure or change
the tank.
Low CO
2
pressure
due to leaks
Repair CO
2
leaks.
Obstruction in the
water or soda line
Clean out the lines.
Beverage is not
sweet enough:
Is the ratio (brix) of
the drink correct?
Flow control out of
adjustment
Adjust the flow control.
Soda flow too high Reset CO
2
pressure or replace
regulator if necessary.
Obstruction in syrup
line
Clean out the syrup line.
Drinks are foaming:
Are system
pressures correct?
Over carbonation Check CO
2
supply. Reset
pressure or replace regulator is
necessary.
Dirty lines/valves Clean/sanitize entire system.
Problem Possible Cause To Correct