Technician’s HandbookThis manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocfsg.comA
10 Part Number STH12 9/10How to Read a Model NumberICE/BEVERAGE MODEL NUMBERSAccessoriesDepending on store type and location, various optional equipme
100 Part Number STH12 9/10Problem Cross-reference GuideX - Specific problem listed in section R - Problem refer to from section with “X” CO2Carbonated
Part Number STH12 9/10 101CO2 Gas SystemOn units not equipped with Air Pump, check all Probable Causes listed below.QualifierProbable CauseCorrective
102 Part Number STH12 9/10Flat drinks (lack of carbonation in carbonated water)Primary Regulator (less than 500 psi [34.5 bar]).CO2 Supply exhausted (
Part Number STH12 9/10 103Flat drinks (lack of carbonation in carbonated water) (continued)Low Pressure CO2 Warning light or buzzer does not go OFF.Le
104 Part Number STH12 9/10Carbonated Water SystemQualifierProbable CauseCorrective ActionFlat drinksMalfunctioning of Refrigeration System.Beverages a
Part Number STH12 9/10 105Beverages at Dispensing Tower are below 40°F (5°C). (continued)Back Flow Preventer.Remove top cover from Remote Refrigeratio
106 Part Number STH12 9/10No carbonated water at any of the dispensing valves No CO2 gas or water present at dispensing valves.Malfunction of Refriger
Part Number STH12 9/10 107No carbonated water at any of the dispensing valves (continued)CO2 gas is present at Dispensing Valves but no water. (contin
108 Part Number STH12 9/10Carbonator pump and motor will not cycle OFF (possibly noisy pump)Little or no carbonated water at dispensing valve.Primary
Part Number STH12 9/10 109Carbonator pump and motor will not cycle OFF (possibly noisy pump) (continued)Carbonated water at dispensing valve.Liquid Le
Part Number STH12 9/10 11Special ApplicationsATTENTION: MARINE INSTALLATIONSNOTE: This unit must be secured to the vessel during installation. Models
110 Part Number STH12 9/10Carbonator pump and motor will not cycle OFF (possibly noisy pump) (continued)Carbon particles in furnished drink.Malfunctio
Part Number STH12 9/10 111Circulating SystemQualifierProbable CauseCorrective ActionWarm drinksDrinks warm throughout the day, warm all the time.Malfu
112 Part Number STH12 9/10Compressed Air SystemUntil repairs can be made on Compressed Air System, place Air/CO2 Change-over Valve in the CO2 Operatin
Part Number STH12 9/10 113No syrup (continued)Air Compressor operates excessively.Leak at Shake Machine, Orange Juice Dispenser or other optional equi
114 Part Number STH12 9/10Dispensing Valve and TowerQualifierProbable CauseCorrective ActionAll corresponding valves dispensing no syrup.Malfunction o
Part Number STH12 9/10 115No carbonated water or insufficient carbonated water in finished drink No Carbonated Water only at one dispensing valve.Carb
116 Part Number STH12 9/10No water or insufficient water in finished drinks All valves dispensing noncarbonated drinks no water.Water Shut-off Valve c
Part Number STH12 9/10 117No water or insufficient water in finished drinks (continued)Problem occurs at all valves on one (1) dispensing tower.No pow
118 Part Number STH12 9/10No water or insufficient water in finished drinks (continued)Foaming of finished products.Nozzles, Syrup Tube Diffusers dirt
Part Number STH12 9/10 119Electrical SystemQualifierProbable CauseCorrective ActionFuse/Circuit Breaker is open.Short Circuit or overload within unit.
12 Part Number STH12 9/10Your warranty card must be returned to activate the warranty on this equipment. If a warranty card is not returned, the warra
120 Part Number STH12 9/10Refrigeration SystemUntil repairs can be made on unit with no Ice Bank, push Refrigeration and Agitator Switch to the OFF po
Part Number STH12 9/10 121Warm drinks (carbonated water temperature over 40°F [5°C]) (continued)Compressor operates with Ice present at water bath.Def
122 Part Number STH12 9/10No carbonated water at any of the dispensing valvesCO2 gas is present at dispensing valves but no Carbonated Water.Malfuncti
Part Number STH12 9/10 123Syrup SystemQualifierProbable CauseCorrective ActionNo syrup or insufficient syrup in finished drink.Syrup Tank is empty. Re
124 Part Number STH12 9/10No syrup of insufficient Syrup in finished drink. (continued)Gas leak at Syrup System. Use a soap solution around all conne
Part Number STH12 9/10 125Water Booster SystemQualifierProbable CauseCorrective ActionLow or no water pressure at noncarbonated beveragesWater Booster
126 Part Number STH12 9/10Low or no water pressure at noncarbonated beverages (continued)Pump and Motor cycles ON and OFF excessively.Leak on Booster
Part Number STH12 9/10 127Water Filter SystemUntil repairs can be made on the Water Filter, place valve handle into “filter By-pass” position.Qualifie
128 Part Number STH12 9/10When the Brix is OFFAir CompressorFiltered Water PressureCO2 High PressureDrink Temperature70 psi (4.8 bar) ON90 psi (6.2 ba
Part Number STH12 9/10 129Bag-In-Box UsageSyrup Tank UsagePressurized Filtered Water Pressure (Water Booster)60 psi (4.1 bar)Medium Syrup Pressure60 p
Part Number STH12 9/10 13InstallationPre-installation ChecklistWhen installing any system, first make sure the major components are available. General
130 Part Number STH12 9/10ProblemProbable CauseSolutionDrink too warm. Refrigeration switch OFF.Turn ON refrigeration switch.Condenser dirty. Have con
Part Number STH12 9/10 131Component Check ProceduresTest Procedures: MPC 64A Timer/Selection PadMPC 64 A Timers can be placed in the test mode as foll
132 Part Number STH12 9/10J-16 Station & Sizes Revision May 28, 2003#1 Stop/Fill #2 Large#3 Medium #4 Small #5 Valve 6 (or nothing on a 5 Valve to
Part Number STH12 9/10 133Dual Transformers *DUAL TRANSFORMERS MUST BE WIRED IN PHASE*To determine whether transformers are wired in phase: With power
134 Part Number STH12 9/10New MPC84A Portion Control BoardA new portion control board, the MPC84A, has been developed to improve the performance and m
Part Number STH12 9/10 135MPC64A Connectors13151121515J20J12LD6J11LD5J10LD4J9LD3J8LD2J7LD1J15OLDJ16J17Model MPC84AP/N 213373
136 Part Number STH12 9/10MPC84A Connectors13111215151J20J14LD8LD7LD5J9LD3J8LD2J7LD1J15NEWJ16J17Model MPC84AP/N 216162J13J12LD6J11LD4J10J1
Part Number STH12 9/10 137FEATURES OF THE NEW MPC84A• Can control up to 8 stations (valves).• Hardware isolation and zero switching to minimize electr
138 Part Number STH12 9/10NOTE: The new MPC84A does not have factory default set times, like the MPC64A does. If a portion size or station looses its
Part Number STH12 9/10 139are the same and go in the same places. The older 5 pin valve connectors will fit on the new board, as long as you observe t
14 Part Number STH12 9/10Post Mix System:Double Check:CO2 regulator setBeverage dispenserBeverage tubingCO2 tankCarbonatorStepless (Oetiker) clampsCha
140 Part Number STH12 9/10MOVs Field TestingMetal Oxide Varistors installed on the water and carbonated water buttons on, McDonalds style dispensing t
Part Number STH12 9/10 141Test Procedures: MPC84C Timer/Selection BoardMPC 84B timers can be placed in the test mode as follows:1. Flip power switch O
142 Part Number STH12 9/10J-16 Station and Sizes:#1 Stop/Fill#2 Large#3 Medium#4 Small#5 Valve 6#6 Valve 5#7 Valve 4#8 Valve 3#9 Valve 2#10 Valve 1#11
Part Number STH12 9/10 143J-17 CALIBRATION BUTTON AND LIGHTIf microprocessor does not go into calibration, remove connector at J-17. With jumper wire,
144 Part Number STH12 9/10Back-flow Preventer MaintenanceThe integral carbonator in this unit is equipped with a back-flow preventer designed to prote
Part Number STH12 9/10 145Head Pressure Control ValveMultiplex remote systems require head pressure control valves with special settings. Replace defe
146 Part Number STH12 9/10be simulated by rinsing the condenser with cool water during the freeze cycle.FAN CYCLE CONTROL VS. HEAD PRESSURE CONTROL VA
Part Number STH12 9/10 147Charging Multiplex Remote Refrigeration Unit NOTE: System would have been opened for repairs. Once completed, a vacuum of 50
148 Part Number STH12 9/10Compressor & Remote CondenserCOMPRESSORNONONOYESNOCOMPRESSORWILL NOT GO OFFCOMPRESSORWILL NOT COME ONVERIFY KEYPAD/DISPL
Part Number STH12 9/10 149Agitator CondenserAGITATORENDYESYESNO/ENDAGITATORWILL NOT GO OFF WITH KEYPAD BUTTON / LED AGITATORWILL NOT COME ON WITH KEYP
Part Number STH12 9/10 15Also consider the location of the following items before installation:Top Mounted Ice Maker InstallationsWater lineDrainPower
150 Part Number STH12 9/10Carbonation System A or BCARBONATOR SYSTEM A OR B YES / END NOCARB MOTOR DOES NOT TURNONCARB MOTOR DOES NOT TURNOFFFIRSTVERI
Part Number STH12 9/10 151Circulation System A or BCIRCULATING SYSTEM A OR B CIRC MOTOR DOES NOT TURNONCIRC MOTOR DOES NOT TURNONVERIFY NO “E1” ERROR
152 Part Number STH12 9/10ERC Control Board, Keypad & DisplayERC CONTROL BOARD AND KEYPAD / DISPLAY KEYPAD / DISPLAY NOT WORKING ERC POWER LED NO
Part Number STH12 9/10 153Programming / Auto SetCOMPRESSOR DOES NOT REACT TO ICE BANK PROBE (SODA & CHILLER UNITS) OR BEER UNIT DOES NOT REACT TO
154 Part Number STH12 9/10ERC Component (Output) Connector LayoutERC Sensor (Input) Connector Layout LL/NCRAGITATIOR CIRCBCARB A CARB B CIRC A EARTH
Part Number STH12 9/10 155Component SpecificationsRefrigeration Unit SpecificationsSuper-Chill units do not apply to the above table, they are only us
156 Part Number STH12 9/10S-250M SpecificationsMII-302 SpecificationsCountertop Weights175 lbs./79.5 kgsIce Storage Capacityup to 250 lbs./ 114 kgs of
Part Number STH12 9/10 157ChartsRefrigerant ChargeR-12 MODEL P/N R-12 OZS/GRAMS16 EUTECTIC 200847 10/1304.137A 903750 73.6/2086.537W 903751 80/2267.9
158 Part Number STH12 9/102803W 902805 6/170.111AS 903722 12/340.237KA 903730 74/2097.837KR 903731 172/4876.137KW 903732 80/2267.938HAC 903806 18/510.
Part Number STH12 9/10 159R-22MODEL P/N R-22 OZS/GRAMS11MA 901106 11/31211MA2C 901108 11/312150MA-1 915011 11/31237KA22 903790 64/181437KR22 903791 15
16 Part Number STH12 9/10S250-M DimensionsIHBAEFGDCA39.81"(101.1 cm)B30.00"(76.2 cm)C9.94"(25.2 cm)D4.44"(11.3 cm)E22.63"(57.
160 Part Number STH12 9/10R-404AMODEL P/N R-404A OZS/GRAMS11M042C 901125 13.5/38311MA04 901120 13.5/383150A04 905121 13.5/3832803A04 902830 10.5/29828
Part Number STH12 9/10 161Operating PressuresNORMAL OPERATING PRESSURES OF REFRIGERATION UNITS1. On system with expansion valve (pressure limiting) ev
162 Part Number STH12 9/10NORMAL OPERATING PRESSURES OF REFRIGERATION UNITS1. On system with expansion valve (pressure limiting) evaporator gets no hi
Part Number STH12 9/10 163McDonald’s Models History*Only 100 units manufactured.Finished Drink @ 5:1 BrixSoda OnlySlow Flow 6 oz. / 4 sec. 5 oz. / 4 s
164 Part Number STH12 9/10Sustained Draw Curve ChartsSC180 SUSTAINED DRAW CURVESC340 SUSTAINED DRAW CURVEFlow Rate (pounds/minute)Inlet Temperature (°
Part Number STH12 9/10 165SC1000 SUSTAINED DRAW CURVESC2000 SUSTAINED DRAW CURVEFlow Rate (pounds/minute)Inlet Temperature (°F)Flow Rate (pounds/minut
166 Part Number STH12 9/10This Page Intentionally Left Blank
Part Number STH12 9/10 167DiagramsWiring DiagramsMODEL 72/72B AIR COOLED 3 PHASELow Pressure StitchCO2 Signal Transformer Right Hand Unit OnlyFan Moto
168 Part Number STH12 9/10MODEL 72/72B AIR COOLED 1 PHASESymbolsWire Nut, Small YellowWire Nut, Large BlackWire Attached to ComponentCarbonator Tan kC
Part Number STH12 9/10 169MODEL 72/72B WATER COOLED 3 PHASELow CO2 Pressure StitchCO2 Signal Transformer Right Hand Unit OnlyHigh Pressure controlComp
Part Number STH12 9/10 17S250-M FOOTPRINTABCDE30.00"(76.2 cm)26.00"(66.0 cm)8.00"(20.3 cm)7.30"(18.5 cm)11.00"(27.9 cm)FGH I
170 Part Number STH12 9/10MODEL 37Air Compressor MotorBlackConduit with WireBlackWhiteWhiteBlackGreenWhiteBlackGreenAgitator MotorCarbonator Tank “A”W
Part Number STH12 9/10 171MODEL 371FContactorRefrig.AgitatorGreenGreenBlackBlackGround ScrewBlackGreenBlueBlueBlueRedRedBlueSecondary Ice Bank Control
172 Part Number STH12 9/10MODEL 37FContactorRedSecondary Ice Bank ControlWhiteWhiteYellowYellowWhiteBlackBrown37AF Fan MotorModel 37AF OnlyAgitator Mo
Part Number STH12 9/10 173MODEL 37TCO2 PanelLamp #6Lamp #7Note: Lamps 6 and 7 are out of CO2 lights located on the dispensing towers. Wiring is provid
174 Part Number STH12 9/10MODEL 37T SCHEMATIC DIAGRAMRefrig. CompressorAJR or Remote Fan MotorCarb. “A” MotorCirc. “A” MotorCarb. “B” MotorCirc. “B” M
Part Number STH12 9/10 175MODEL 37KCO2 PanelAgit. MotorCarb. Tank “A”Carb. Tank “B”Remote FanWith Remote Condenser OnlyHigh Pressure Cut-outWith Air C
176 Part Number STH12 9/10MODEL 37K SCHEMATIC DIAGRAMCarb. “A” MotorCirc. “A” MotorLow Incoming Water Press Warning LightGrn/YelLt. BluBlkRedBrnIncomi
Part Number STH12 9/10 177MODEL 44A & R WIRING DIAGRAMAgitator MotorCarb. Pump MotorCirc. Pump MotorBlkWhtWhtBluWhtBlkWhtRibbed ConductorGreenBlac
178 Part Number STH12 9/10MODEL 44K WIRING DIAGRAMComponent LegendMS Relay Motor StartSW Switch ON/OFFPS Pressure SwitchCR Control RelayLLC Liquid Lev
Part Number STH12 9/10 179MODEL 44K22Compressor Switch #1Agitator Switch #2Carbonator Switch #3Circulator Switch #4Lamp 4Lamp 3Lamp 2LLC “B”LoadRibbed
18 Part Number STH12 9/10MII-250 DimensionsNMLKHPDEFGCBAA39.00"(99.1 cm)B12.50"(31.8 cm)C30.00"(76.2 cm)D1.50"(3.8 cm)E9.94"(
180 Part Number STH12 9/10MODEL 44M04 SCHEMATIC DIAGRAMComponent LegendMS Relay Motor StartSW Switch ON/OFFPS Pressure SwitchCR Control RelayLLC Liqui
Part Number STH12 9/10 181MODEL 50HCompressorRunStartSingle Phase Units OnlyBrnBrnRedBrownBlackBrownBrnRedBlkBrownRedBlackCompressorFan MotorAgitator
182 Part Number STH12 9/10MODEL 50M04Component LegendMS Relay Motor StartSW Switch ON/OFFPS Pressure SwitchCR Control RelayLLC Liquid Level ControlIBC
Part Number STH12 9/10 183FRONT DRAW TOWER WIRING DIAGRAMGrn/YelRedBlkWater SwitchKey BoardSoda SwitchControlOFF-ON SwitchSpliceBlkBrnRedOrgYe lGrnBlu
184 Part Number STH12 9/10PASS-THROUGH TOWER WIRING DIAGRAM24 VACRef. ConduitOFF-ON SW24 VACLow CO2 LampLow CO2 LampCO2 Pressure SW On Refrig. UnitWat
Part Number STH12 9/10 185Soda Wiring DiagramsMODEL 2803 (120V 60 HZ)Fan Motor (Air Cooled Only)Start CapacitorCompressorO/LRIBCarbonator TankIce Bank
186 Part Number STH12 9/10MODEL 2803 (230V 60 HZ)Fan Motor (Air Cooled Only)Start CapacitorCompressorO/LYelCarbonator Ta nkIce Bank ControlBrnBluPress
Part Number STH12 9/10 187MODEL 2803 INTERNATIONAL (230V 50 HZ)Fan Motor (Air Cooled Only)Start CapacitorCompressorO/LCarbonator TankIce Bank ControlB
188 Part Number STH12 9/10MODEL 2803 ELECTRONIC IBC
Part Number STH12 9/10 189MODEL 11 Agitator MotorCarbonator MotorCarbonator MotorAgitator MotorCarbonator MotorCirculator MotorRefrigeration UnitCarbo
Part Number STH12 9/10 19MII-250 FOOTPRINTABCDE30.00"(76.2 cm)26.00"(66.0 cm)8.00"(20.3 cm)8.00"(20.3 cm)11.00"(27.9 cm)FGH I
190 Part Number STH12 9/10MODEL 11 ELECTRONIC IBC(BLK)(BRN)(BLK)(RED)(BLUE)(BLK)(YEL)(RED)(L1)USED ON MODELSSS901120SS901122SS901139ONLY(RIBBED)(213)(
Part Number STH12 9/10 191MODEL 42 & 44 ELECTRONIC IBC
192 Part Number STH12 9/10MODEL 42 & 44 (WITH ERC 50 HZ)50HZ 50HZ
Part Number STH12 9/10 193MODEL 42 & 44 (WITH ERC 60 HZ)60HZ 60HZ
194 Part Number STH12 9/10MODEL 44 (120V 60 HZ)Component LegendMS Relay Motor StartSW Switch ON/OFFPS Pressure SwitchCR Control RelayLLC Liquid Level
Part Number STH12 9/10 195MODEL 44 (230V 60 HZ)Compressor SW#1Agitator SW#2Carbonator SW#3Circulator SW#4High Pressure Cut-outFan Motor(Air Unit Only)
196 Part Number STH12 9/10MODEL 50 (50 HZ)50HZ 50HZModels50MAX04 TS905053-35350MRX04 TS905054-35350MWX04 TS905055-353Caution: Disconnect power before
Part Number STH12 9/10 197MODEL 50 (60 HZ)60HZ 60HZModels50MA04 TS905050-36350MR04 TS905051-36350MW04 TS905052-36350MR04Q/T TS905046-263Caution: Disco
198 Part Number STH12 9/10MODEL 50 (WITH ERC 50 HZ)50HZ 50HZModelsCaution: Disconnect power before working on electrical circuitry.See Serial Plate fo
Part Number STH12 9/10 199MODEL 50 (WITH ERC 60 HZ)60HZ 60HZModelsCaution: Disconnect power before working on electrical circuitry.See Serial Plate fo
20 Part Number STH12 9/10MII-302 DimensionsAHKLDMNOPQFEGJCBA33.25"(84.5 cm)B12.50"(31.8 cm)C42.75"(108.6 cm)D1.38"(3.5 cm)E5.59&qu
200 Part Number STH12 9/10Super-Chil Wiring DiagramsMODEL SC180 (120 VAC)Component LegendL1 Line 1L2 NeutralM MotorMS ContactorPS Pressure SwitchIBC I
Part Number STH12 9/10 201MODEL SC180 ELECTRONIC IBC
202 Part Number STH12 9/10MODEL SC340 (120 VAC)Component LegendL1 Line 1L2 NeutralM MotorMS ContactorPS Pressure SwitchIBC Ice Bank ControlOptional Ci
Part Number STH12 9/10 203MODEL SC340 (120 VAC)
204 Part Number STH12 9/10MODEL SC900 & SC1000
Part Number STH12 9/10 205MODEL SC1000 (230 VAC)Component LegendL1 Line 1L2 NeutralM MotorMS ContactorPS Pressure SwitchIBC Ice Bank ControlAgitator M
206 Part Number STH12 9/10MODEL SC1000 ELECTRONIC IBC
Part Number STH12 9/10 207MODEL SC1000 (WITH ERC 50 HZ)50HZ 50HZ
208 Part Number STH12 9/10MODEL SC1000 (WITH ERC 60 HZ)60HZ 60HZ
Part Number STH12 9/10 209MODEL SC2000 (50 HZ)50HZ 50HZModelsSC2000AX TS905063-353SC2000RX TS905064-353SC2000WX TS905065-353Caution: Disconnect power
Part Number STH12 9/10 21MII-302 FOOTPRINTABCD42.75"(108.6 cm)38.75"(98.4 cm)8.00"(20.3 cm)8.00"(20.3 cm)EFGH17.38"(44.1 cm)1
210 Part Number STH12 9/10MODEL SC2000 (60 HZ)60HZ 60HZModelsSC2000A TS905060-363SC2000R TS905061-363SC2000W TS905062-363Caution: Disconnect power bef
Part Number STH12 9/10 211WIRING DIAGRAM FRONT DRAW TOWERGrn/YelRedBlkWater SwitchKey BoardSoda SwitchControlOFF-ON SwitchSpliceBlkBrnRedOrgYe lGrnBlu
212 Part Number STH12 9/10Circuit SchematicsPLUMBING CIRCUIT DIAGRAMS — MODEL 280312345 61234563/8" Barb x 3/8" TubeDispensing Tower Syrup B
Part Number STH12 9/10 213PLUMBING CIRCUIT DIAGRAMS — MODEL 11M ROOT BEERSingle Tower PlumbingInstallation Kit(020001441)02000140300861302Pressurized
214 Part Number STH12 9/10Model 11M Root Beer Dual Tower Plumbing Installation Kit(020001441)02000140300861302Pressurized Filtered Water SupplyPrimary
Part Number STH12 9/10 215Model 11M Root Beer Three Tower PlumbingInstallation Kit(020001441)02000140300861302Pressurized Filtered Water SupplyPrimary
216 Part Number STH12 9/10PLUMBING CIRCUIT DIAGRAMS — MODEL 44MPressurized Water Circuit DiagramTo Coffee MachineTo Ice MachinePhosphate Feeder (optio
Part Number STH12 9/10 217Pre-mix Plumbing — Six Valve Towers with Connection at Center IslandNOTE: Other plumbing configurations are possible. Check
218 Part Number STH12 9/106123456123456123456543216A5A4A3A2A1W6123456A5A4A3A2A1WTwo Tower Systemwith Connection at Center IslandSelf Serve or Center I
Part Number STH12 9/10 2196123456123456123456543216A5A4A3A2A1W6123456A5A4A3A2A1W6123456A5A4A3A2A1WThree Tower Systemwith Connection at Center IslandSe
22 Part Number STH12 9/10MII-250 Installation KitNo. Part Number Description Qty.1 00854998 Ell 1/2 x 3/8 Barb SS 22 00861304 Splicer 3/8 x 3/8 Barb 7
220 Part Number STH12 9/10Pre-mix Plumbing — Eight Valve Towers with Connection at Center Island6543216A5A4A3A2A1W77A88A612345876123458761234587Single
Part Number STH12 9/10 221654321786A5A4A3A2A1W7A8A6123458761234587612345876A5A4A3A2A1W7A8A61234578Two Tower Systemwith Connection at Center IslandSelf
222 Part Number STH12 9/10654321786A5A4A3A2A1W7A8A6123458761234587612345876A5A4A3A2A1W7A8A612345786A5A4A3A2A1W7A8A61234578Three Tower Systemwith Conne
Part Number STH12 9/10 223Carbonated Water Plumbing — Six Valve Towers with Connection at UnitSupplies Carbonated Water to Diet Drink and Provides Con
224 Part Number STH12 9/106A5A4A3A2A1WW98W986A5A4A3A2A1WW98Two Tower System with Connection at UnitSelf Serve or Center Island TowerDrive-thru TowerPr
Part Number STH12 9/10 2256A5A4A3A2A1W8986A5A4A3A2A1WW98899WWW6A5A4A3A2A1WThree Tower System with Connection at UnitSelf Serve or Center Island TowerD
226 Part Number STH12 9/10Carbonated Water Plumbing — Eight Valve Towers with Connection at Unit6A5A4A3A2A1WW98W987A8ASingle Tower System with Connect
Part Number STH12 9/10 227W98W98W986A5A4A3A2A1W7A8A6A5A4A3A2A1W7A8ATwo Tower System with Connection at UnitSelf Serve or Center Island TowerDrive-thru
228 Part Number STH12 9/10996A5A4A3A2A1W7A8A8 98W6A5A4A3A2A1W7A8A6A5A4A3A2A1W7A8AW8W8 9WThree Tower System with Connection at UnitSelf Serve or Center
Part Number STH12 9/10 229PLUMBING CIRCUIT DIAGRAMS — MODEL 50MPressurized Water Circuit DiagramDispensing TowerDispensing TowerDispensing TowerSyrup
Part Number STH12 9/10 23MII-302 Installation KitWATER AND SYRUP LINESThis kit facilitates connecting the unit to a 12-16 line conduit, with one or tw
230 Part Number STH12 9/10CO2 Gas and Compressed Air Circuit DiagramCarbonator Tank “B”Legend— Manual Shut-off Valve— Check Valve, Ball — Manual 3-way
Part Number STH12 9/10 231Ice/Beverage Units DiagramsSERVEND RECOMMENDED PLUMBINGS-250M Plumbing DiagramManifold: Change to carbonated or non-carbonat
232 Part Number STH12 9/10MII-250 Plumbing DiagramManifold: Change to carbonated or non-carbonated water.1. Rotate plunger 180° using a 5/32" All
Part Number STH12 9/10 233MII-302 Plumbing DiagramManifold: Change to carbonated or non-carbonated water (S2-SII only).1. Rotate plunger 180° using a
234 Part Number STH12 9/10This Page Intentionally Left Blank
Manitowoc Foodservice2100 Future DriveSellersburg, IN 47172, USAPh: 812-246-7000 Fax: 812-246-7024Visit us online at: www.manitowocfsg.com© 2010 Mani
24 Part Number STH12 9/10down through the counter top, to connect to the conduit. It will also be necessary to fully insulate this new added section b
Part Number STH12 9/10 25SYRUP LINES• Unit has eight syrup lines.• Use seven @ 1/4 x 3/8" and one @ 1/4 x 1/2" elbows and proper size condui
26 Part Number STH12 9/10REMOTE CONDENSER LINESET REQUIREMENTS1. Both the discharge and liquid remote condensing lines must be kept to a minimum dista
Part Number STH12 9/10 273. The easiest method to create a trap is to bend the tubing (smoothly, no kinks) into the trap form.4. The trap(s) must be o
28 Part Number STH12 9/10Safe Installation Dos and Don’ts! WarningRead the following warnings before beginning aninstallation. Failure to do so may re
Part Number STH12 9/10 29• DO check that all flare fittings are tight. This check must be performed with a wrench to ensure a quality seal.• DO inspec
Safety NoticesAs you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this handbook. Disregarding the notices may
30 Part Number STH12 9/10Location RequirementsSODA REFRIGERATION UNIT “QUICK-PICK” SELECTION CHARTNumber of Dispensing StationsBusiness Level* 1 2 3 4
Part Number STH12 9/10 31Select a location for the refrigeration unit that meets the requirements of the building plans, local codes, and personnel. T
32 Part Number STH12 9/103. Connect the water manifold supply line, located on the bulkhead panel in the motor compartment to the main water supply. T
Part Number STH12 9/10 33WATER SUPPLY1. Use the built in fill valve that is already plumbed into the unit.2. An appropriate floor drain is required wi
34 Part Number STH12 9/10ElectricalGENERALMINIMUM CIRCUIT AMPACITYThe minimum circuit ampacity is used to help select the wire size of the electrical
Part Number STH12 9/10 35SPECIFICATIONS* Only the model 50M with SS part numbers have 120V components, the TS does not.Model Volt/Cycle/PhaseMinimum
36 Part Number STH12 9/10GROUNDING INSTRUCTIONSThis appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of
Part Number STH12 9/10 37!WarningWhen using electric appliances, basicprecautions must always be followed, includingthe following:a. Read all the inst
38 Part Number STH12 9/10Plumbing/Water SupplyPLUMBING POTABLE WATERA 1" (2.54 cm) ID copper inlet water line equipped with a 3/4" (1.905 cm
Part Number STH12 9/10 39Preparing Ice Bank – Non-ERCBUILDING AN ICE BANK1. At this time, fill the unit water bath tank to the top, or within 1/2"
Read These Before Proceeding:!CautionProper installation, care and maintenance areessential for maximum performance and trouble-free operation of your
40 Part Number STH12 9/105. Turn on the main water supply to the booster assembly. Verify the booster is plugged in and that the accumulator tank valv
Part Number STH12 9/10 41Preparing Ice Bank with ERCBUILDING AN ICE BANK1. At this time, fill the unit water bath tank to the top, or within 1/2"
42 Part Number STH12 9/105. Turn on the main water supply to the booster assembly. Verify the booster is plugged in and that the accumulator tank valv
Part Number STH12 9/10 43Component IdentificationTypical SystemConduit (In Wall)6 Valve Soda Towe r8 Valve Soda Towe rWater BoosterAir CompressorCondu
44 Part Number STH12 9/10ConnectionsMODEL 2803 CONNECTIONSJohn Guest FittingsDrain HoseControl Switches1/4" Plastic CO2 Line from CarbonatorRight
Part Number STH12 9/10 45MODEL 11M CONNECTIONSJohn Guest FittingsDrain HoseControl SwitchesOpening for Conduit Supply Lines
46 Part Number STH12 9/10MODEL 42, 44, & 50M CONNECTIONSJohn Guest FittingsDrain HoseControl Switches (Non-ERC)Opening for Conduit Supply LinesERC
Part Number STH12 9/10 47ERC CONTROL BOARD OUTPUT CONNENCTIONSLL/NCRAGITATIOR CIRCBCARB A CARB B CIRC A EARTH PLUG THIS PIN
48 Part Number STH12 9/10ERC CONTROL BOARD INPUT CONNENCTIONS12 11 10 9 8 7 6 5 4 3 2 1 CO2 TS TD TW TB TA WL ICE CA A CA B HPCO
Part Number STH12 9/10 49MaintenanceMaintenance ScheduleThis section provides a list of periodic maintenance tasks and the scheduled frequency require
Part Number STH12 9/10 5Table of ContentsGeneral InformationModel Numbers . . . . . . . . . . . . . . . . . . . . . 9How to Read a Model Number . . .
50 Part Number STH12 9/10• Inspect air compressor to verify cut-in at 70 psi (4.8 bar) and cut-out at 90 psi (6.3 bar). Adjust pressure switch if nece
Part Number STH12 9/10 51Syrup supplyDaily (365 times per year)• Clean general area of syrup hookup with soap and warm water. Rinse off all soap.Every
52 Part Number STH12 9/10and syrup to water ratios at each dispensing station. Adjust as required.• Inspect beverage conduits for damage. Re-insulate
Part Number STH12 9/10 53• If pressure is low, inspect water filter cartridges to ensure they are able to supply adequate water pressure under normal
54 Part Number STH12 9/10Cleaning and Sanitizing the Dispensing Valves and Product LinesMAINTENANCE SCHEDULEEvery dayDispensing valvesRemove nozzles a
Part Number STH12 9/10 55CLEANING EQUIPMENT AND SUPPLIES• Recommended cleaner: Any caustic-base (low sudsing, non-perfumed, easily rinsed) detergent s
56 Part Number STH12 9/10CLEANING AND SANITIZING PROCEDURENOTE: Cleaning and sanitizing is not required for potable water circuits. Potable water line
Part Number STH12 9/10 572. Flush the cleaning solution from the lines with clean water after a minimum of 3 minutes, by pulsing the valves as describ
58 Part Number STH12 9/10SanitizingBEVERAGE SYSTEM CLEANINGSanitize the beverage system at initial start-up as well as regularly scheduled cleaning. T
Part Number STH12 9/10 59• Bucket 3 — mix a solution of unscented bleach (5% Na CL O) or commercial sanitizer and warm to hot water. Mixture should su
6 Part Number STH12 9/10Start-up (Non-ERC) . . . . . . . . . . . . . . . . . 72Sequence of Operation (Non-ERC) . . . . 74Start-up (with ERC) . . .
60 Part Number STH12 9/104. Connect syrup connector to BIB connector and immerse both into Bucket 1. A “bag-side” connector can be created by cutting
Part Number STH12 9/10 61FIGAL BEVERAGE SYSTEM1. Prepare the following in three clean Figal tanks:• Rinse tank - fill with room temperature tap water.
62 Part Number STH12 9/1011. Reconnect syrup and carbonated water lines.12. Draw syrup through the lines to rinse the system. Discard drinks until at
Part Number STH12 9/10 63OperationHow the Multiplex WorksModel 2803 — a 1/3 HP refrigeration unit that will provide pre-mix carbonated beverages and c
64 Part Number STH12 9/10Model 50M — a 2.2 HP Pre-mix refrigeration unit that will provide pre-mix carbonated beverages and chilled carbonated water f
Part Number STH12 9/10 65• The TS compressor is mounted with bolts instead of studs. • TS remote and water-cooled back panel connections are offset to
66 Part Number STH12 9/10WATER MANIFOLD TS• TS air-cooled condenser comes standard with a filter.Two Stainless Steel log style manifolds• One regulate
Part Number STH12 9/10 67ELECTRICAL TS• Electrical compartment has been moved up on the unit to eliminate water intrusion potential from the pump comp
68 Part Number STH12 9/10WATER BATH ACCESS SSWATER BATH ACCESS TS• Has a round hole in the front and back panels with no edge trim to protect lines.•
Part Number STH12 9/10 69SERVICE ACCESS SS• Front panel was solid and did not allow easy access for service.• Switch panel was mounted flush to end pa
Part Number STH12 9/10 7ERC Component (Output) Connector Layout 154ERC Sensor (Input) Connector Layout . 154Component SpecificationsRefrigeration Un
70 Part Number STH12 9/10SERVICE ACCESS TS WITH ERC• Service Switch — (SER) switch, press to send ID on power line network.• Wink Function — LED flash
Part Number STH12 9/10 71Equipment Setup Procedure (Non-ERC)1. Ensure that all valve nozzles are attached to the valves.2. Observe pressure of CO2 hig
72 Part Number STH12 9/10Start-up (Non-ERC)1. Fill the refrigeration unit water bath tank with water to within 1/2" (1.27 cm) of the top of the o
Part Number STH12 9/10 73PLACING THE CARBONATION SYSTEM IN OPERATION1. Open the CO2 gas supply valve at CO2 tanks or bulk tank. Adjust the CO2 pressur
74 Part Number STH12 9/10Sequence of Operation (Non-ERC)PRE-MIX REFRIGERATION UNITIce Bank Is Required1. Check water bath for full ice bank.2. The sta
Part Number STH12 9/10 75Multiplex Pre-mix Beverage System Operation and LayoutConduit (In Wall)6 Valve Soda Towe r8 Valve Soda Towe rWater BoosterAir
76 Part Number STH12 9/10Start-up (with ERC)PLACING EQUIPMENT IN OPERATIONBefore placing equipment in operation, verify that all requirements for roof
Part Number STH12 9/10 77PLACING THE SYRUP SYSTEM IN OPERATION1. Open the CO2 gas supply valve at CO2 tanks or bulk tank. Adjust the CO2 pressure to 9
78 Part Number STH12 9/10Sequence of Operation (with ERC)ELECTRONIC CONTROLPrerequisites• Potable water must be connected to the carbonator pump circu
Part Number STH12 9/10 79Power InterruptionDuring a power interruption the control will resume from the point of interruption when power is reapplied
8 Part Number STH12 9/10This Page Intentionally Left Blank
80 Part Number STH12 9/10PGM Switch• Used to enter and exit programming modes. • Press PGM Switch F000 will display• Press and hold Carb A switch — Di
Part Number STH12 9/10 81• Press and hold Carb B switch — Display will indicate one of the following:• Cb00 — Low and High Probes are open (carbonator
82 Part Number STH12 9/10Program Mode 4Temporarily cancel display of error codes. Cancelling the error codes allows circulating glycol temperatures to
Part Number STH12 9/10 83Multiplex Electronic Refrigeration Control (ERC) ProgrammingSUPPLY POWER ONAGITATOR COMES ON CONSTANTLYCOMPRESSOR DELAY SHOWS
84 Part Number STH12 9/10Equipment Close Procedure — All Units1. Clean the underside of the dispensing tower around the nozzle area with a clean damp
Part Number STH12 9/10 85MULTIPLEX ELECTRONIC REFRIGERATION CONTROL (ERC) PROGRAMMINGPOWER UP DELAYSHOWS “Pd30”AND COUNTSDOWN TO “Pd00"SUPPLY POW
86 Part Number STH12 9/10“C000”(CONDUCTIVITY)PRESS COMP/AGITSWITCH TO SHOW ICEBANK PROBE“CC11” = NO ICECOMPRESSOR ON“CC10”= ICE ON LOWSENSOR COMPRESSO
Part Number STH12 9/10 87TroubleshootingElectronic Refrigeration Control (ERC) Model Error Codes• Error codes will interrupt the temperature display a
88 Part Number STH12 9/10ERROR CODES E1, E2, & E3 FLOWCHARTEIYESNONORMALLY CAUSED BY WATER PRESSURE <5 PSI FOR 5 SECONDSMUST STAY ABOVE 10 PSI
Part Number STH12 9/10 89VERIFY INCOMING WATER SUPPLY PRESSURE TO UNIT >15 PSI OR NOT WITH ANOTHER GAUGE IN THE SUPPLY SYSTEM EREPLACE ERC CIRCUIT
Part Number STH12 9/10 9General InformationModel NumbersThis manual covers the following models: (A) Air Cooled (W) Water Cooled (R) Remote Cooled280
90 Part Number STH12 9/10ERROR CODES E4, E5, & E6 FLOWCHARTEIE2 E3 E4 E5 E6 E7 E8 E9NORMALLY CAUSED BY WATER BATH TEMPERATURE > 45°F NORMALLY C
Part Number STH12 9/10 91NOYES YESNOYES NOPRESSUREVERIFIED TEMPERATUREVERIFIED VERIFY TEMPERATURE WITH SECOND THERMOMETERTROUBLE SHOOT WATER SUPPLY SY
92 Part Number STH12 9/10ERROR CODES E7, E8, & E9 FLOWCHARTEIE2 E3 E4 E5 E6 E7 E8 E9NORMALLY CAUSED BY CARB MOTOR A RUNNING > 7 MINUTES CONTINU
Part Number STH12 9/10 93NONOYESYESYESNO“E7” ERROR GOES AWAY PUMP GOODUN-PLUG ICE BANK PROBE CONNECTOR (#3) FROM ERC BOARDRESET ERROR (PUSH CARB A AND
94 Part Number STH12 9/10COMPONENT TROUBLESHOOTINGFAN / REMOTE CONDENSERREFRIGERATIONSYSTEM AGITATORCOMPRESSORYESYESNO/ENDNOOUTPUT TERMINALS ARE COMMO
Part Number STH12 9/10 95ENDNONONOYESNOYESELSEPROBESREPLACEERCCONTROLBOARD020001985VERIFY VOLTAGE ON ERCAGITATORTERMINALSPULL ICE BANK CONN ON ERC, CO
96 Part Number STH12 9/10CIRCULATING SYSTEM A OR B ERC CONTROL BOARD AND KEYPAD / DISPLAY CARBONATOR SYSTEM A OR B YES / END CARB MOTOR DOES NOT TURN
Part Number STH12 9/10 97NONOYESNOCHECK ALL WIRES ANDCONNECTORS TO CIRC MOTOR, CHECK CIRC MOTORDISPLAY SHOWS POWER UP COUNTDOWN“PdXX” VOLTAGE AT ERC A
98 Part Number STH12 9/10ChecklistIf a problem arises during operation of your post mix soda refrigeration unit, follow the checklist below. Routine a
Part Number STH12 9/10 99Beverage dispensed is too sweet:Is the ratio (brix) of the drink correct?Flow control out of adjustmentAdjust the flow contro