Manitowoc I0500 Spezifikationen Seite 201

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 270
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 200
Part Number STH025 02/12 201
Harvest Cycle
REMOTE CONDENSER
The head pressure control cycles into full bypass due
to the pressure drop when the harvest valve opens.
Refrigerant flows from the compressor to the
evaporator through the harvest valve and the head
pressure valve is out of the circuit.
Undercharge Symptoms
Safety limit #1 or Safety limit #2 in control board
memory.
Harvest cycle suction pressure is low.
Harvest cycle discharge pressure is low.
Liquid line entering receiver feels warm to hot in
the freeze cycle.
Overcharge Symptoms
Safety limit #2 in control board memory.
Harvest cycle suction pressure is low.
Harvest cycle discharge pressure is normal.
Freeze cycle time, suction and discharge pressure
are normal and the ice machine will not harvest.
The sheet of ice cubes show little or no sign of
melting when removed from the evaporator after
the harvest cycle has been completed. (If the
cubes are melted you have a release problem,
clean the ice machine).
Seitenansicht 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 269 270

Kommentare zu diesen Handbüchern

Keine Kommentare