Touch Pad Diagnostics
Follow the control board diagnostics to the Status
Passed display. Perform the following keystrokes on
the display.
Display reads Status Passed, press the right arrow
Display reads Pass Yes, press the right arrow
Display reads Key Pad Test, press the right arrow
4. Test the functionality of all buttons on the touch
pad.
NOTE: Pushing the power button will start and stop
the ice machine. Testing it last will allow the ice
machine to continue running a freeze cycle.
As you press the buttons the first letter of the
corresponding word will flash indicating the push
button is operating correctly
Press the right arrow 5 times rapidly to exit.
5. Display reads Pass Yes and Pass No.
Press left arrow 4 times to exit to home screen.