144 Part Number 80-1479-3 7/10
PROBLEM: WATER WILL NOT RUN INTO THE
SUMP TROUGH DURING THE FREEZE CYCLE
Step 1 Verify water is supplied to the ice
machine.Start a new Freeze sequence by moving the
ICE/OFF/CLEAN toggle switch to OFF, then back to
ICE.
Step 2 Wait until the freeze cycle starts
(approximately 45 seconds, the freeze cycle starts
when the compressor energizes).
Important
This rest art must be d one p rior to performing
diagnostic procedures. This assures the ice machine
is not in a freeze cycle wate r inlet valve safety shut-
off mode. You must complete the entire di agnostics
within 6 minutes of starting.