Manitowoc S0850M Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Eiswürfelmacher Manitowoc S0850M herunter. Manitowoc S0850M Service manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Thank you for selecting a Manitowoc Ice Machine, the dependability leader in ice making equipment and related products.
With proper installation, care and maintenance, your new Manitowoc Ice Machine will provide you with many years of
reliable and economical performance.
S Model
S0850M
Ice Machines
Service
Manual
Part Number 80-1558-3
4/2004
Seitenansicht 0
1 2 3 4 5 6 ... 99 100

Inhaltsverzeichnis

Seite 1 - Ice Machines

Thank you for selecting a Manitowoc Ice Machine, the dependability leader in ice making equipment and related products. With proper installation, care

Seite 2 - Procedural Notices

General Information Section 11-4 Part Number 80-1558-3Owner Warranty Registration CardGENERALThe packet containing this manual also includes warranty

Seite 3 - Table of Contents

Attend A Manitowoc Factory Service School• Improve Your Service Techniques• Network with Your Peers• 4 1/2 Days of Intensive Training on Manitowoc Ice

Seite 4 - Part No. 80-1558-3

Section 2 Installation Instructions Part Number 80-1558-3 2-1Section 2Installation InstructionsGeneralThese instructions are provided to assist the qu

Seite 5 - Part No. 80-1558-3 1-3

Installation Instructions Section 22-2 Part Number 80-1558-3Location of Ice MachineThe location selected for the ice machine must meet the following c

Seite 6 - 1-4 Part No. 80-1558-3

Section 2 Installation Instructions Part Number 80-1558-3 2-3Electrical ServiceGENERALVOLTAGEThe maximum allowable voltage variation is ±10% of the ra

Seite 7 - General Information

Installation Instructions Section 22-4 Part Number 80-1558-3Self-Contained Electrical Wiring ConnectionsSELF CONTAINED ICE MACHINE115/1/60 OR 208-230/

Seite 8 - Accessories

Section 2 Installation Instructions Part Number 80-1558-3 2-5Water Supply and Drain RequirementsWATER SUPPLYLocal water conditions may require treatme

Seite 9 - Model/Serial Number Location

Installation Instructions Section 22-6 Part Number 80-1558-3WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONSTypical Water Supply Drain Installation!Caut

Seite 10 - Warranty Coverage

Section 2 Installation Instructions Part Number 80-1558-3 2-7Installation Check ListIs the Ice Machine level?Has all of the internal packing been remo

Seite 11 - Installation Instructions

Installation Instructions Section 22-8 Part Number 80-1558-3Before Starting the Ice MachineAll Manitowoc ice machines are factory-operated and adjuste

Seite 12 - Ice Machine Heat of Rejection

Section 3 Ice Machine Operation Part Number 80-1558-3 3-1Section 3Ice Machine OperationComponent Identificationsv3150sv3149Check ValveIce Thickness Pr

Seite 13 - Electrical Service

We reserve the right to make product improvements at any time.Specifications and design are subject to change without notice. Safety NoticesAs you wor

Seite 14 - For United Kingdom Only

Ice Machine Operation Section 33-2 Part Number 80-1558-3Sequence Of OperationNOTE: The toggle switch must be in the ice position and the water curtain

Seite 15 - (Water-Cooled Models)

Section 3 Ice Machine Operation Part Number 80-1558-3 3-3HARVEST SEQUENCE5. Water PurgeThe harvest valve(s) opens at the beginning of the water purge

Seite 16

Ice Machine Operation Section 33-4 Part Number 80-1558-3Operational ChecksGENERALManitowoc ice machines are factory-operated and adjusted before shipm

Seite 17 - Installation Check List

Section 3 Ice Machine Operation Part Number 80-1558-3 3-5HARVEST SEQUENCE WATER PURGEThe harvest sequence water purge adjustment may be used when the

Seite 18 - Part Number 80-1558-3

Ice Machine Operation Section 33-6 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK

Seite 19 - Ice Machine Operation

Section 4 Maintenance Part Number 80-1558-3 4-1Section 4MaintenanceGeneralYou are responsible for maintaining the ice machine in accordance with the i

Seite 20 - Sequence Of Operation

Maintenance Section 44-2 Part Number 80-1558-3Guardian™Slime is a leading cause of ice machine breakdowns and biological growth is a health concern. T

Seite 21 - Part Number 80-1558-3 3-3

Section 4 Maintenance Part Number 80-1558-3 4-3Interior Cleaning and SanitizingGENERALClean and sanitize the ice machine every six months for efficien

Seite 22 - Operational Checks

Maintenance Section 44-4 Part Number 80-1558-3SANITIZING PROCEDUREUse sanitizer to remove algae or slime. Do not use it to remove lime scale or other

Seite 23 - Important

Section 4 Maintenance Part Number 80-1558-3 4-5REMOVAL OF PARTS FOR CLEANING/SANITIZING1. Turn off the electrical and water supply to the ice machine

Seite 24

Part No. 80-1558-3 1-1Table of ContentsSection 1 General InformationModel Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 25 - Maintenance

Maintenance Section 44-6 Part Number 80-1558-31. Water CurtainA. Gently flex the curtain in the center and remove it from the right side.B. Slide the

Seite 26 - Guardian™

Section 4 Maintenance Part Number 80-1558-3 4-73. Water Distribution TubeNOTE: Distribution tube thumbscrews are retained by o-rings to prevent loss.

Seite 27 - Section 4 Maintenance

Maintenance Section 44-8 Part Number 80-1558-3Water Level Probe1. Remove the water trough.2. The water level probe normally does not require removal f

Seite 28

Section 4 Maintenance Part Number 80-1558-3 4-9Water Dump ValveThe water dump valve normally does not require removal for cleaning. To determine if re

Seite 29

Maintenance Section 44-10 Part Number 80-1558-3Evaporator Tray Removal1. Remove the water trough.2. Remove thumbscrew on left side of tray.3. Allow le

Seite 30

Section 4 Maintenance Part Number 80-1558-3 4-11Water Inlet ValveThe water inlet valve normally does not require removal for cleaning. Refer to Sectio

Seite 31

Maintenance Section 44-12 Part Number 80-1558-3Removal from Service/WinterizationGENERALSpecial precautions must be taken if the ice machine is to be

Seite 32

Section 5 Before Calling For Service Part Number 80-1558-3 5-1Section 5Before Calling For ServiceChecklistIf a problem arises during operation of your

Seite 33

Before Calling For Service Section 55-2 Part Number 80-1558-3Safety Limit FeatureIn addition to the standard safety controls, such as the high pressur

Seite 34

Section 6 Electrical System Part Number 80-1558-3 6-1Section 6Electrical SystemEnergized Parts ChartsSELF-CONTAINED WATER-COOLED MODELS1. Initial Sta

Seite 35 - Removing the Front Panel

Table of Contents (continued)1-2 Part No. 80-1558-3Section 3 Ice Machine OperationComponent Identification . . . . . . . . . . . . . . . . . . . . .

Seite 36

Electrical System Section 66-2 Part Number 80-1558-3Wiring Diagram Sequence of Operation SELF-CONTAINED MODELSInitial Start-Up or Start-Up After Autom

Seite 37 - Before Calling For Service

Section 6 Electrical System Part Number 80-1558-3 6-32. REFRIGERATION SYSTEM START-UPThe compressor starts after the 45-second water purge, and it rem

Seite 38 - Safety Limit Feature

Electrical System Section 66-4 Part Number 80-1558-3Freeze Sequence3. PRE-CHILLTo pre-chill the evaporator, the compressor runs for 30 seconds (60 sec

Seite 39 - Electrical System

Section 6 Electrical System Part Number 80-1558-3 6-54. FREEZEThe water pump starts after the pre-chill. An even flow of water is directed across the

Seite 40 - Operation

Electrical System Section 66-6 Part Number 80-1558-3Harvest Sequence5. WATER PURGEThe harvest valve(s) opens at the beginning of the water purge to di

Seite 41 - Section 6 Electrical System

Section 6 Electrical System Part Number 80-1558-3 6-76. HARVESTThe harvest valve(s) remains open and the refrigerant gas warms the evaporator. This ca

Seite 42

Electrical System Section 66-8 Part Number 80-1558-3Automatic Shut-Off7. AUTOMATIC SHUT-OFFWhen the storage bin is full at the end of a harvest cycle,

Seite 43

Section 6 Electrical System Part Number 80-1558-3 6-9Wiring DiagramsThe following pages contain electrical wiring diagrams. Be sure you are referring

Seite 44

Electrical System Section 66-10 Part Number 80-1558-3S0850M - SELF CONTAINED - 1 PHASE SV3130(89)(55)(88)(42)High Pressure CutoutWater ValveHarvest Va

Seite 45

Section 6 Electrical System Part Number 80-1558-3 6-11S0850M - SELF CONTAINED - 3 PHASESV3131(89)(55)(88)(42)High Pressure CutoutWater ValveHarvest Va

Seite 46

Table of Contents (continued)Part No. 80-1558-3 1-3Section 6 Electrical SystemEnergized Parts Charts . . . . . . . . . . . . . . . . . . . . . . . .

Seite 47 - Wiring Diagrams

Electrical System Section 66-12 Part Number 80-1558-3Component Specifications and DiagnosticsMAIN FUSEFunctionThe control board fuse stops ice machine

Seite 48

Section 6 Electrical System Part Number 80-1558-3 6-13SymptomsBin Switch Fails Open• The ice machine will not start with the toggle switch in the ice

Seite 49

Electrical System Section 66-14 Part Number 80-1558-3COMPRESSOR ELECTRICAL DIAGNOSTICSThe compressor will not start or will trip repeatedly on overloa

Seite 50

Section 6 Electrical System Part Number 80-1558-3 6-15PTCR DIAGNOSTICSWhat is a PTCR?A PTCR (or Positive Temperature Coefficient Resistor) is made fro

Seite 51

Electrical System Section 66-16 Part Number 80-1558-3S-Model Automatic Shut-Off and RestartWhen the storage bin is full at the end of a harvest cycle,

Seite 52

Section 6 Electrical System Part Number 80-1558-3 6-17There are other problems that may cause compressor start-up failure with a good PTCR in a new, p

Seite 53

Electrical System Section 66-18 Part Number 80-1558-3DIAGNOSING START COMPONENTSIf the compressor attempts to start, or hums and trips the overload pr

Seite 54

Section 6 Electrical System Part Number 80-1558-3 6-19ELECTRONIC CONTROL BOARDControl BoardSV3129AC LINE VOLTAGE ELECTRICAL PLUG (NUMBERS MARKED ON WI

Seite 55

Electrical System Section 66-20 Part Number 80-1558-3General S-Model control boards use a dual voltage transformer. This means only one control board

Seite 56

Section 6 Electrical System Part Number 80-1558-3 6-21Ice Thickness Probe (Harvest Initiation)HOW THE PROBE WORKSManitowoc’s electronic sensing circui

Seite 57

Table of Contents (continued)1-4 Part No. 80-1558-3Cycle Time/24 Hour Ice Production/Refrigerant Pressure Charts . . . . . . . . . 7-19Refrigerant

Seite 58

Electrical System Section 66-22 Part Number 80-1558-3DIAGNOSING ICE THICKNESS CONTROL CIRCUITRYIce Machine Does Not Cycle Into Harvest When Water Cont

Seite 59

Section 6 Electrical System Part Number 80-1558-3 6-23Water Level Control CircuitryWATER LEVEL PROBE LIGHTThe water level probe circuit can be monitor

Seite 60

Electrical System Section 66-24 Part Number 80-1558-3DIAGNOSING WATER LEVEL CONTROL CIRCUITRYProblem: Water Trough Overfilling During The Freeze Cycle

Seite 61 - Water Level Control Circuitry

Section 6 Electrical System Part Number 80-1558-3 6-25Problem: Water Will Not Run Into The Sump Trough During The Freeze CycleStep 1 Verify water is

Seite 62

Electrical System Section 66-26 Part Number 80-1558-3Diagnosing An Ice Machine That Will Not Run!WarningHigh (line) voltage is applied to the control

Seite 63

Section 6 Electrical System Part Number 80-1558-3 6-27S0850M - SELF CONTAINED - 1 PHASE WITH TERMINAL BOARDSV2071213456

Seite 64

Electrical System Section 66-28 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK

Seite 65

Section 7 . Refrigeration System Part Number 80-1558-3 7-1Section 7.Refrigeration SystemSequence of OperationSELF-CONTAINED WATER -COOLED MODELSFigure

Seite 66

. Refrigeration System Section 77-2 Part Number 80-1558-3Figure 7-2. Self-Contained Harvest Cycle Harvest Cycle Refrigeration SequenceHot gas flows th

Seite 67 - Refrigeration System

Section 7 . Refrigeration System Part Number 80-1558-3 7-3Operational Analysis (Diagnostics)GENERALWhen analyzing the refrigeration system, it is impo

Seite 68

Section 1 General Information Part Number 80-1558-3 1-1Section 1General InformationModel NumbersThis manual covers the following models: NOTE: Model n

Seite 69 - Part Number 80-1558-3 7-3

. Refrigeration System Section 77-4 Part Number 80-1558-3BEFORE BEGINNING SERVICEIce machines may experience operational problems only during certain

Seite 70

Section 7 . Refrigeration System Part Number 80-1558-3 7-5INSTALLATION/VISUAL INSPECTION CHECKLIST WATER SYSTEM CHECKLISTA water-related problem often

Seite 71

. Refrigeration System Section 77-6 Part Number 80-1558-3ICE FORMATION PATTERNEvaporator ice formation pattern analysis is helpful in ice machine diag

Seite 72

Section 7 . Refrigeration System Part Number 80-1558-3 7-73. Extremely Thin at Evaporator InletThere is no ice, or a considerable lack of ice formatio

Seite 73 - Part Number 80-1558-3 7-7

. Refrigeration System Section 77-8 Part Number 80-1558-3SAFETY LIMITSGeneralIn addition to standard safety controls, such as high pressure cut-out, t

Seite 74

Section 7 . Refrigeration System Part Number 80-1558-3 7-9Safety Limit #1Refer to previous page for safety limit operation.Freeze time exceeds 60 minu

Seite 75

. Refrigeration System Section 77-10 Part Number 80-1558-3Safety Limit #2Refer to page 7-8 for safety limit operation.Harvest time exceeds 3.5 minutes

Seite 76

Section 7 . Refrigeration System Part Number 80-1558-3 7-11ANALYZING DISCHARGE PRESSUREDURING FREEZE OR HARVEST CYCLEProcedure1. Determine the ice mac

Seite 77

. Refrigeration System Section 77-12 Part Number 80-1558-3ANALYZING SUCTION PRESSUREDURING FREEZE CYCLEThe suction pressure gradually drops throughout

Seite 78

Section 7 . Refrigeration System Part Number 80-1558-3 7-13Freeze Cycle Suction Pressure High ChecklistFreeze Cycle Suction Pressure Low ChecklistNOTE

Seite 79

General Information Section 11-2 Part Number 80-1558-3AccessoriesContact your Manitowoc distributor for these optional accessories:BIN CASTERReplaces

Seite 80

. Refrigeration System Section 77-14 Part Number 80-1558-3SINGLE EXPANSION VALVE ICE MACHINES -COMPARING EVAPORATOR INLET AND OUTLET TEMPERATURESNOTE:

Seite 81

Section 7 . Refrigeration System Part Number 80-1558-3 7-15HARVEST VALVE TEMPERATURE CHECKGeneralA harvest valve requires a critical orifice size. Thi

Seite 82 - √) in the small boxes

. Refrigeration System Section 77-16 Part Number 80-1558-3HOW TO USE THE REFRIGERATION SYSTEMOPERATIONAL ANALYSIS TABLESGeneralThese tables must be us

Seite 83

Section 7 . Refrigeration System Part Number 80-1558-3 7-17REFRIGERATION SYSTEM OPERATIONAL ANALYSIS TABLES S Models Single Expansion ValveThis table

Seite 84 - Diagnostics

. Refrigeration System Section 77-18 Part Number 80-1558-3Pressure Control Specifications and DiagnosticsHIGH PRESSURE CUT-OUT (HPCO) CONTROLFunctionS

Seite 85 - Refrigerant Pressure Charts

Section 7 . Refrigeration System Part Number 80-1558-3 7-19Cycle Time/24 Hour Ice Production/Refrigerant Pressure ChartsThese charts are used as guide

Seite 86

. Refrigeration System Section 77-20 Part Number 80-1558-3Refrigerant Recovery/Evacuation and RechargingNORMAL SELF-CONTAINED MODEL PROCEDURESRefriger

Seite 87

Section 7 . Refrigeration System Part Number 80-1558-3 7-21Self-Contained Charging Procedures1. Be sure the toggle switch is in the OFF position.Figur

Seite 88

. Refrigeration System Section 77-22 Part Number 80-1558-3Figure 7-9. Recovery/Evacuation ConnectionsxxxSCHRAEDER FITTINGQUICK CONNECTDISCHARGE LINECO

Seite 89

Section 7 . Refrigeration System Part Number 80-1558-3 7-23SYSTEM CONTAMINATION CLEAN-UPGeneralThis section describes the basic requirements for resto

Seite 90

Section 1 General Information Part Number 80-1558-3 1-3Model/Serial Number LocationThese numbers are required when requesting information from your lo

Seite 91

. Refrigeration System Section 77-24 Part Number 80-1558-3Mild System Contamination Cleanup Procedure1. Replace any failed components.2. If the compre

Seite 92

Section 7 . Refrigeration System Part Number 80-1558-3 7-2510. Follow the normal evacuation procedure, except replace the evacuation step with the fol

Seite 93

. Refrigeration System Section 77-26 Part Number 80-1558-3Figure 7-10. Using Pinch-Off ToolSV1406

Seite 94

Section 7 . Refrigeration System Part Number 80-1558-3 7-27FILTER-DRIERSThe filter-driers used on Manitowoc ice machines are manufactured to Manitowoc

Seite 95

. Refrigeration System Section 77-28 Part Number 80-1558-3REFRIGERANT DEFINITIONSRecoverTo remove refrigerant, in any condition, from a system and sto

Seite 96

Section 7 . Refrigeration System Part Number 80-1558-3 7-29REFRIGERANT RE-USE POLICYManitowoc recognizes and supports the need for proper handling, re

Seite 97 - Part Number 80-1558-3 7-31

. Refrigeration System Section 77-30 Part Number 80-1558-3HFC REFRIGERANT QUESTIONS AND ANSWERSManitowoc uses R-404A and R-134A HFC refrigerants with

Seite 98

Section 7 . Refrigeration System Part Number 80-1558-3 7-31THIS PAGE INTENTIONALLY LEFT BLANK

Seite 99

. Refrigeration System Section 77-32 Part Number 80-1558-3THIS PAGE INTENTIONALLY LEFT BLANK

Kommentare zu diesen Handbüchern

Keine Kommentare