Manitowoc RF0300 Spezifikationen Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 192
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
Part Number 000007661 6/12 31
4. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
5. Use the solution and a brush or sponge to clean
all disassembled components and the inside of
the bin.
6. Rinse all cleaned parts with clear water.
7. Mix a solution of sanitizer and water.
8. Soak the parts in the sanitizer/water solution for
10 minutes. Use the sanitizer/water solution and a
sponge to sanitize all removed components and
the inside of the bin. Do not rinse the sanitized
parts.
9. Continue with step 11 of the cleaning/sanitizing
procedure.
Solution Type Water Mixed With
Sanitizer 3 gal. (11 L) 2 oz (60 ml) sanitizer
Part Number 94-0565-3