Manitowoc QD0422A Spezifikationen Seite 106

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 105
98 Part Number STH044 10/13
Severe System Contamination
1. Remove the refrigerant charge.
2. Remove the compressor.
3. Wipe away any burnout deposits from suction and
discharge lines at compressor.
4. Sweep through the open system with dry
nitrogen.
5. Install a new compressor and new start
components.
6. Install a suction line filter-drier with acid and
moisture removal capability. Place the filter drier
as close to the compressor as possible.
7. Install an access valve at the inlet of the suction
line drier.
8. Install a new liquid line drier.
Important
Refrigerant sweeps are not recommended, as they
release refrigerant into the atmosphere.
Seitenansicht 105
1 2 ... 101 102 103 104 105 106 107 108 109 110 111 ... 123 124

Kommentare zu diesen Handbüchern

Keine Kommentare