Part Number STH038 5/12 33
Step 8 While components are soaking, use 1/2 of the
cleaner/water solution to clean all food zone surfaces
of the ice machine and bin (or dispenser). Use a nylon
brush or cloth to thoroughly clean the following ice
machine areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom,
and sides
Bin or dispenser
Rinse all areas thoroughly with clean water.
SANITIZING PROCEDURE
Step 9 Mix a solution of sanitizer and lukewarm
water.
Step 10 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a spray bottle
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
Solution
Type
Water Mixed With
Sanitizer 12 L (3 gal) 60 ml (2 oz) sanitizer